Teguex
®
FFL
Expansion Joints
DN 500-DN 2600
Colour Inner Outer Max temp. Applications
Label tube cover °C
Red EPDM EPDM 90° Hot water, cooling water with salt solutions,
chlorine solutions, esters and ketones.
Yellow Nitrile Chloro- 90° Water, salt solutions, alkalis, mineral oils,
prene vegetable or animal oils, oils aerosols,
butane or propane gas, etc.
White Nitrile Chloro- 90° Drinking water, food and beverages.
white prene Including fats and oils.
Green Hypalon Chloro- 90° Strong and/or concentrated acids, etc.
prene Compressed air that bears oil aerosols.
Materials
Applications
For cooling water systems at power plants, in gas
and drinking-water supply lines, at condensers, for
pumps, turbines and boilers for the absorption of
movements, oscillations, noises and vibrations.
These expansion joints are suitable for large
extensions in axial, lateral or angular directions.
They are suitable in pressurised large-sized pipe
systems with requirements for small reaction forces,
providing high reliability and long life.
Design
Rubber bellow with high convolution and therefore
highly exible. Able to compensate for high
movements due to its low inherent resistance.
Steel backing anges with supporting collar to
ensure the smooth movement of the bellow.
Note: Other materials available. Please ask.
Pressure Temperature Pressure
Max. working pressure 90°C 10 bar
Test pressure 20°C 15 bar
Burst pressure 20°C >30 bar
Pressure rating
Type U
Standard unit for axial, lateral
and angular movements.
Type L
Unit with tie bars for
lateral movements.
Type A
Unit with hinges to take up
angular movements in one plane.
Style A
Style B